FloLogic

FloLogic Remote I/O

FloLogic Remote I/O

Regular price $205.00
Tax included. Shipping Free by UPS Ground

Product Details

01-0400/RIO

Stop nuisance shutoffs without giving up leak protection. A FloLogic valve protects your home by shutting off the water when it sees flow that runs longer than normal. That's exactly what you want for a burst pipe. It's not what you want when the sprinklers run for 45 minutes, the softener regenerates at 2 a.m., or the pool tops itself off. The FloLogic Remote I/O (input/output) module is a wireless bridge that tells your FloLogic System when that long water use is planned, so the valve stays open for it. It still catches real leaks the rest of the time.

See exactly how it installs: free 11-page illustrated setup guide

Step-by-step pairing with photos, app setup screens, and wiring diagrams for irrigation, water softeners, pool fill, hot-water recirculation pumps and alarm systems.

View the Remote I/O Setup Guide (PDF) ↗

Opens in a new tab · PDF, about 6 MB

Why add a Remote I/O to your shutoff valve

  • No more false shutoffs from scheduled equipment. Irrigation, softener regeneration, pool and fountain fills, and other long-running devices can use water without tripping the valve.
  • Protection stays on when those devices are off. Flow timers are suspended only while the connected device is active. Once it finishes, normal leak detection resumes automatically.
  • Wireless, so it's a cleaner install. The Remote I/O talks to your FloLogic Gateway over Thread wireless, so you can mount it right next to the irrigation controller, softener or pool equipment. You don't need long control wires running back to the valve. It's ideal for larger homes and estates.
  • Your other systems react to the valve. Outputs can turn off a hot-water recirculation pump when the water is shut off, alert your security system, or signal a well-pump control.
  • Simple setup in the FloLogic app. Name each input (for example, "Irrigation"), choose the action (for example, "Override"), and the system responds automatically whenever that device turns on.

How it works

Each Remote I/O module has two configurable inputs and two configurable outputs.

Inputs accept wired dry-contact closures or voltage signals (maximum 24 VAC/VDC). You assign each input an action in the app:

  • Override: disables flow timers for as long as the signal is present, then reactivates them when it ends. This is ideal for irrigation controllers.
  • Bypass / External Bypass: a momentary contact starts a Bypass timer that disables flow timers for a fixed time. This is ideal for a softener backwash.
  • Home / Away: switches System modes automatically, for example when a security system is armed or disarmed.
  • External Auto Shutoff: closes the valve when a third-party moisture or low-temperature sensor trips.

Outputs are normally open relay contacts that close when a selected FloLogic state is active: Water Off, Automatic Shutoff, Away Mode or System Trouble. Use them to signal alarm panels, smart-home systems or pump controls. Pumps need an external relay: a 120 V relay for recirculation pumps or a 220 V relay for well pumps.

Typical applications

Device Typical connection Result
Irrigation controller Master Valve (MV) or Pump Start + Common → Input
See wiring diagram (p. 7) ↗
Override while zones run
Water softener Flow switch on the drain/discharge line → Input
See wiring diagram (p. 8) ↗
Timed Bypass during regeneration
Pool or fountain auto-fill Relay or flow switch → Input
See wiring diagram (p. 9) ↗
No shutoff during fill cycles.
Note: Most pool auto-fillers can be handled by adjusting Home/Away flow-time settings, with no flow switch needed.
Security / alarm system Arm/disarm contact → Input
See wiring diagram (p. 11) ↗
Automatic Home/Away mode
Hot-water recirculation pump Output → 120 V relay
See wiring diagram (p. 10) ↗
Pump powers off when water is shut off or the home is in Away mode
Well pump Output → 220 V relay
See functions table (p. 5) ↗
Pump control tied to valve status
Moisture or freeze sensors Sensor dry contact → Input
See functions table (p. 5) ↗
External auto shutoff
Alarm / central-station monitoring Output → alarm panel zone
See wiring diagram (p. 11) ↗
Leak shutoff and System Trouble alerts

Compatibility and requirements

  • Requires a FloLogic System with a Gateway Module (Gateway Connect), provisioned online in the FloLogic app. Not compatible with the older WiFi-only Connect Module.
  • Requires a 120 VAC outlet near the mounting location.
  • Mount indoors or in a protected location, away from water and excessive moisture.
  • Input wiring: 16–18 AWG is typical for dry-contact and low-voltage (24 VAC/VDC or lower) runs.

What's in the box

Remote I/O module, input and output screw terminal blocks, USB-C power cable, AC power block and mounting hardware.

See the provisioning and device connection instructions here (11-page PDF, opens in a new tab) ↗